設計 · 木構造
木造柱の火災時設計軸圧縮耐力 (EN 1995-1-2)
EN 1995-1-2 第4.2.2項による座屈低減係数を含む火災時木造柱の設計軸圧縮耐力: NcRdfi = kcfi · Aef · fc0dfi.
- EN 1995-1-2:2004
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 火災時残存断面の座屈低減係数 | 1 | ||
| 有効残存断面積 | mm² | ||
| 火災時繊維方向設計圧縮強度 | N/m² | ||
| 火災時設計軸圧縮耐力 | kN | Result |
例題
= 0.65 1 · = 20,164 mm² · = 27,600,000 N/m²
= 361.74 kN
Standard and source
- Standard
- EN 1995-1-2:2004
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.