設計 · 木構造
座屈低減係数kc
柱の曲げ座屈に対する低減係数: kc = min(1.0 / (k + √(k² - λrel,c²)); 1.0)。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 座屈補助係数 | – | ||
| 相対細長比 | – | ||
| 座屈低減係数 | – | Result |
例題
= 1.69593 · = 1.46903
= 0.39318 · Source: EN 1995-1-1:2004 式 (6.25)
Scope and standard
EN 1995-1-1 6.3.2項による木材圧縮部材。
- Standard
- EN 1995-1-1:2004、6.3.2 (3)項、式 (6.25)
- Result
- (dimensionless)
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は設計 › 木構造で開始されます。
Miaknows the formula catalog and asks for what is missing.