設計 · 鋼構造

すみ肉溶接の等価応力 σeq

  • タイプ:作用効果
  • バージョン1
  • 2026/11/10にレビュー済み

EN 1993-1-8 4.5.3.2式4.1によるすみ肉溶接の等価フォンミーゼス応力:σeq = √(σperp² + 3 · (τperp² + τpar²))。

σeq=σperp2+3⋅(τperp2+τpar2)\displaystyle \sigma _{eq} = \sqrt{\sigma _{perp}^2 + 3 \cdot (\tau _{perp}^2 + \tau _{par}^2)}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

σperpτperpτparσeq

Formula and quantities

SymbolNameUnitNote
σperp\displaystyle \sigma_{perp}のど面に垂直な法線応力N/m²
τperp\displaystyle \tau_{perp}溶接軸に垂直なせん断応力N/m²
τpar\displaystyle \tau_{par}溶接軸に平行なせん断応力N/m²
σeq\displaystyle \sigma_{eq}等価フォンミーゼス溶接応力N/m²Result

例題

σperp\displaystyle \sigma_{perp} = 80,000,000 N/m² · τperp\displaystyle \tau_{perp} = 60,000,000 N/m² · τpar\displaystyle \tau_{par} = 70,000,000 N/m²

σeq\displaystyle \sigma_{eq} = 178,610,000 N/m²

Standard and source

Result
σeq\displaystyle \sigma_{eq} in MPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
σeq\displaystyle \sigma_{eq} = 178,606,000 N/m²= sqrt((80,000,000 N/m²)² + 3 · ((60,000,000 N/m²)² + (70,000,000 N/m²)²))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は設計 › 鋼構造で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.