EN 1993-1-9 第7.1(1)項による1億回繰返しにおけるせん断応力範囲の打切り限界: ΔτL = 0.457 · ΔτC.

ΔτL=0.457⋅ΔτC\displaystyle \Delta\tau_{L} = 0.457 \cdot \Delta\tau_{\mathrm{C}}
  • EN 1993-1-9:2005
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

ΔτCΔτL

Formula and quantities

SymbolNameUnitNote
ΔτC\displaystyle \Delta\tau_{\mathrm{C}}200万回繰返しにおけるせん断ディテール等級基準強度N/m²
ΔτL\displaystyle \Delta\tau_{L}せん断疲労打切り限界N/m²Result

例題

ΔτC\displaystyle \Delta\tau_{\mathrm{C}} = 80,000,000 N/m²

ΔτL\displaystyle \Delta\tau_{L} = 36,560,000 N/m²

Standard and source

Standard
EN 1993-1-9:2005
Result
ΔτL\displaystyle \Delta\tau_{L} in MPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
ΔτL\displaystyle \Delta\tau_{L} = 36,560,000 N/m²= 0.457 · (80,000,000 N/m²)