設計 · 接合部

ボルトせん断利用率 ηv

  • タイプ:検証
  • バージョン1
  • 2026/11/13にレビュー済み

せん断力を受けるボルトの照査: ηv = Fv,Ed / Fv,Rd。

ηv=Fv,Ed/Fv,Rd\displaystyle \eta _{v} = F_{v,\mathrm{Ed}} / F_{v,\mathrm{Rd}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

FvEdFvRdηv

Formula and quantities

SymbolNameUnitNote
Fv,Ed\displaystyle F_{v,\mathrm{Ed}}ボルト1本あたりの設計せん断力kN
Fv,Rd\displaystyle F_{v,\mathrm{Rd}}ボルト1本あたりの設計せん断耐力kN
ηv\displaystyle \eta_{v}ボルトせん断利用率1Result

例題

Fv,Ed\displaystyle F_{v,\mathrm{Ed}} = 65 kN · Fv,Rd\displaystyle F_{v,\mathrm{Rd}} = 94.08 kN

ηv\displaystyle \eta_{v} = 0.691 1

Standard and source

Result
ηv\displaystyle \eta_{v} in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
ηv\displaystyle \eta_{v} = 0.690901 1= (65 kN) / (94.08 kN)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は設計 › 接合部で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.