地盤工学 · 土圧
擁壁の転倒照査比 (EN 1997-1)
EN 1997-1 第2.4.7.2項(EQU)による重力式または片持ち式擁壁の転倒釣合い照査比: ηot = Mdst / Mstb.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 設計不安定転倒モーメント | kNm | ||
| 設計安定抵抗モーメント | kNm | ||
| 転倒照査比(<= 1.0) | 1 | Result |
例題
= 180 kNm · = 300 kNm
= 0.6 1
Standard and source
- Standard
- EN 1997-1:2004
- Result
- in 1
Reference to clause and equation, no standard text. The description is written in our own words.