地盤工学 · 沈下

限界動水勾配 icrit

  • タイプ:特性値
  • バージョン1
  • 2026/11/12にレビュー済み

パイピング/ボイリングの限界動水勾配: icrit = (γsat - γw) / γw。

icrit=γsat−γwγw\displaystyle i_\mathrm{crit} = \frac{\gamma_\mathrm{sat} - \gamma_{w}}{\gamma_{w}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

icritγsatγw

Formula and quantities

SymbolNameUnitNote
γsat\displaystyle \gamma_\mathrm{sat}地盤の飽和単位体積重量kN/m³
γw\displaystyle \gamma_{w}水の単位体積重量kN/m³
icrit\displaystyle i_\mathrm{crit}限界動水勾配–Result

例題

γsat\displaystyle \gamma_\mathrm{sat} = 20 kN/m³ · γw\displaystyle \gamma_{w} = 9.81 kN/m³

icrit\displaystyle i_\mathrm{crit} = 1.0387 · Source: EN 1997-1:2004 第10.3条

Scope and standard

EN 1997-1第10.3項に基づく上向き浸透流によるボイリング照査。

Standard
EN 1997-1:2004、10.3項、式 (10.2)
Result
icrit\displaystyle i_\mathrm{crit} (dimensionless)

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
icrit\displaystyle i_\mathrm{crit} = 1.03874= ((20 kN/m³) - (9.81 kN/m³)) / (9.81 kN/m³)