設計 · コンクリート構造
単位長さ当たりねじりスターラップ Asw/s
EN 1992-1-1 式(6.26)に基づく単位長さ当たり必要ねじりリンク補強量。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 設計ねじりモーメント | Nm | ||
| 中心線で囲まれる面積 | mm² | ||
| リンクの設計降伏強度 | N/mm² | ||
| 圧縮斜材角度のコタンジェント | – | ||
| 単位長さ当たり必要ねじりリンク面積 | mm | Result |
例題
= 30,000 Nm · = 120,000 mm² · = 435 N/mm² · = 1.5
= 0.1916 mm · Source: EN 1992-1-1:2004 式 (6.26)
Scope and standard
EN 1992-1-1に基づくねじりせん断補強を有するコンクリート梁。
- Standard
- EN 1992-1-1:2004、6.3.2 (3)項、式 (6.26)
- Result
- in mm²/mm
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は設計 › コンクリート構造で開始されます。
Miaknows the formula catalog and asks for what is missing.