設計 · コンクリート構造

圧縮斜材の破壊に支配される最大せん断耐力 VRd,max

  • タイプ:耐力
  • バージョン1
  • 2026/11/9にレビュー済み

垂直スターラップによるコンクリート圧縮斜材の破壊で制限される最大せん断力: VRd,max = αcw · bw · z · ν1 · fcd / (cotθ + 1 / cotθ)。

VRd,max=αcw⋅bw⋅z⋅ν1⋅fcdcot⁡θ+tan⁡θ\displaystyle V_{\mathrm{Rd},\mathrm{max}} = \frac{\alpha_{cw} \cdot b_{w} \cdot z \cdot \nu_{1} \cdot f_{cd}}{\cot\theta + \tan\theta}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

bwzVRd,maxfcd

Formula and quantities

SymbolNameUnitNote
αcw\displaystyle \alpha_{cw}圧縮側応力状態の係数–
bw\displaystyle b_{w}ウェブ幅m
z\displaystyle z内部レバーアームm
ν1\displaystyle \nu_{1}ひび割れコンクリートの強度低減係数–
fcd\displaystyle f_{cd}コンクリートの設計圧縮強度N/mm²
cot⁡θ\displaystyle \cot\theta圧縮斜材傾斜角θのコタンジェント–
VRd,max\displaystyle V_{\mathrm{Rd},\mathrm{max}}圧縮斜材の最大せん断耐力kNResult

例題

αcw\displaystyle \alpha_{cw} = 1 · bw\displaystyle b_{w} = 0.3 m · z\displaystyle z = 0.45 m · ν1\displaystyle \nu_{1} = 0.528 · fcd\displaystyle f_{cd} = 17 N/mm² · cot⁡θ\displaystyle \cot\theta = 2.5

VRd,max\displaystyle V_{\mathrm{Rd},\mathrm{max}} = 417.85 kN · Source: EN 1992-1-1:2004 式 (6.9)

Scope and standard

垂直せん断補強筋(α = 90度)および 1.0 <= cot(θ) <= 2.5 の梁。

Standard
EN 1992-1-1:2004、6.2.3 (3)項、式 (6.9)
Result
VRd,max\displaystyle V_{\mathrm{Rd},\mathrm{max}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
VRd,max\displaystyle V_{\mathrm{Rd},\mathrm{max}} = 417.848 kN= 1 · (0.3 m) · (0.45 m) · 0.528 · (17 N/mm²) / (2.5 + 1 / 2.5)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は設計 › コンクリート構造で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.