設計 · 複合構造
完全せん断結合に必要なスタッド本数 nf
完全せん断結合のために臨界区間に必要なシアコネクタ本数:nf = min(Ncf, Npl,a) / PRd。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| コンクリートフランジの塑性圧縮耐力 | kN | ||
| 形鋼断面の塑性軸耐力 | kN | ||
| シアコネクタ1本の設計せん断耐力 | kN | ||
| 必要シアコネクタ本数 | 1 | Result |
例題
= 4,080 kN · = 2,580.85 kN · = 81.66 kN
= 31.6
Standard and source
- Standard
- EN 1994-1-1:2004
- Result
- in 1
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は設計 › 複合構造で開始されます。
Miaknows the formula catalog and asks for what is missing.