設計 · アルミ構造
HAZ低減引張強さ fu,haz
溶接部近傍の熱影響部(HAZ)における低減引張強さ: fu,haz = ρu,haz · fu。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 引張強さに対するHAZ軟化係数 | 1 | ||
| 母材の特性引張強さ | N/m² | ||
| HAZ低減引張強さ | N/m² | Result |
例題
= 0.6 · = 310,000,000 N/m²
= 186,000,000 N/m²
Standard and source
- Standard
- EN 1999-1-1:2007
- Result
- in MPa
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は設計 › アルミ構造で開始されます。
Miaknows the formula catalog and asks for what is missing.