設計 · 木構造
3面加熱に対する木材の有効残存せい (EN 1995-1-2)
EN 1995-1-2 第4.2.2項による3面加熱(底面・両側面)長方形木造梁の有効残存せい: hef = h - def.
- EN 1995-1-2:2004
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 元の木材断面せい | mm | ||
| 有効炭化深さ | mm | ||
| 有効残存せい | mm | Result |
例題
= 400 mm · = 49 mm
= 351 mm
Standard and source
- Standard
- EN 1995-1-2:2004
- Result
- in mm
Reference to clause and equation, no standard text. The description is written in our own words.