設計 · 木構造

4面加熱に対する木材の有効残存断面積 (EN 1995-1-2)

  • タイプ:特性値
  • バージョン1
  • 2026/11/21にレビュー済み

EN 1995-1-2 第4.2.2項による4面加熱長方形木造柱の有効残存断面積: Aef = (b - 2 · def) · (h - 2 · def).

Aef=(b−2def)⋅(h−2def)\displaystyle A_{\mathrm{ef}} = (b - 2 d_{\mathrm{ef}}) \cdot (h - 2 d_{\mathrm{ef}})
  • EN 1995-1-2:2004
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

yzbh

Formula and quantities

SymbolNameUnitNote
b\displaystyle b元の木材断面幅mm
h\displaystyle h元の木材断面せいmm
def\displaystyle d_{\mathrm{ef}}有効炭化深さmm
Aef\displaystyle A_{\mathrm{ef}}有効残存断面積mm²Result

例題

b\displaystyle b = 240 mm · h\displaystyle h = 240 mm · def\displaystyle d_{\mathrm{ef}} = 49 mm

Aef\displaystyle A_{\mathrm{ef}} = 20,164 mm²

Standard and source

Standard
EN 1995-1-2:2004
Result
Aef\displaystyle A_{\mathrm{ef}} in mm²

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Aef\displaystyle A_{\mathrm{ef}} = 20,164 mm²= ((240 mm) - 2 · (49 mm)) · ((240 mm) - 2 · (49 mm))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は設計 › 木構造で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.