設計 · 木構造
接合具両側せん断耐力 モードk Fv,Rk
EN 1995-1-1 式8.7kによる両側せん断木材接合モードkの特性耐力:Fv,Rk = 1.15 · √(2 · β / (1 + β)) · √(2 · My,Rk · fh,1,k · d)。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 埋込み強度比 | 1 | ||
| 接合具の降伏モーメント | kNm | ||
| 側材の埋込み強度 | N/m² | ||
| 接合具径 | mm | ||
| モードkの特性耐力 | kN | Result |
例題
= 1 · = 0.32 kNm · = 24,000,000 N/m² · = 16 mm
= 18.01 kN
Standard and source
- Standard
- EN 1995-1-1:2004
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は設計 › 木構造で開始されます。
Miaknows the formula catalog and asks for what is missing.