設計 · 鋼構造
両縁支持板要素の平板座屈低減係数 ρ (EN 1993-1-5)
EN 1993-1-5 第4.4(2)項による両縁支持圧縮板要素(λp > 0.5 + √(0.085 - 0.055 · ψ))のウィンター平板座屈低減係数 rho: ρ = (λp - 0.055 · (3 + ψ)) / λp².
- EN 1993-1-5:2006
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 平板の相対細長比 | 1 | ||
| 縁応力比 sigma_2 / sigma_1 | 1 | ||
| 平板座屈低減係数 | 1 | Result |
例題
= 1.2 · = 1
= 0.680556
Standard and source
- Standard
- EN 1993-1-5:2006
- Result
- in 1
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は設計 › 鋼構造で開始されます。
Miaknows the formula catalog and asks for what is missing.