設計 · 鋼構造
ベースプレート有効片持ち張り出し長さ c
EN 1993-1-8 6.2.5 式6.4に基づく柱脚ベースプレートの有効片持ち張り出し幅 c:c = t · √(fy / (3 · fjd · γM0))。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| ベースプレート厚さ | mm | ||
| ベースプレート鋼材降伏強度 | N/m² | ||
| コンクリート継手の設計支圧強度 | N/m² | ||
| 部分係数 gamma_M0 | 1 | ||
| 有効片持ち張り出し長さ | mm | Result |
例題
= 25 mm · = 235,000,000 N/m² · = 18,000,000 N/m² · = 1
= 52.15 mm
Standard and source
- Standard
- EN 1993-1-8:2005
- Result
- in mm
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は設計 › 鋼構造で開始されます。
Miaknows the formula catalog and asks for what is missing.