設計 · 組積造構造
組積造の特性せん断強度
縦目地充填組積造の特性せん断強度:fvk = min(fvk0 + 0.4 · σd, fvk,lim)。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 初期特性せん断強度 | N/mm² | ≥ 0 | |
| せん断面に垂直な設計圧縮応力 | N/mm² | ≥ 0 | |
| 特性せん断強度の上限値 | N/mm² | > 0 | |
| 組積造の特性せん断強度 | N/mm² | Result |
例題
上限値以下
= 0.2 N/mm² · = 0.8 N/mm² · = 1 N/mm²
= 0.52 N/mm² · Source: 手計算
上限値で制限
= 0.2 N/mm² · = 2.5 N/mm² · = 1 N/mm²
= 1 N/mm² · Source: 手計算
Scope and standard
EN 1996-1-1 条項 3.6.2 に基づく鉛直圧縮応力を伴うせん断下の組積造。
- Standard
- EN 1996-1-1-2005-a1:2012、3.6.2項、式 (3.5)
- Result
- in N/mm²
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は設計 › 組積造構造で開始されます。
Miaknows the formula catalog and asks for what is missing.