設計 · 接合部

コンクリート縁端破壊のせん断偏心係数 ψec,V (EN 1992-4)

  • タイプ:特性値
  • バージョン1
  • 2026/11/25にレビュー済み

EN 1992-4 第7.2.2.5項 式(7.46)による縁端近傍のファスナー群に作用する偏心せん断荷重の群効果係数: ψecV = 1 / (1 + 2 · eV / (3 · c1)).

ψecV=1/(1+2⋅eV/(3⋅c1))\displaystyle \psi _{ecV} = 1 / (1 + 2 \cdot e_{V} / (3 \cdot c_{1}))
  • EN 1992-4:2018
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

c1eVψecV

Formula and quantities

SymbolNameUnitNote
eV\displaystyle e_{V}合力せん断荷重の偏心距離mm
c1\displaystyle c_{1}荷重方向の縁端距離mm
ψecV\displaystyle \psi_{ecV}せん断偏心係数1Result

例題

eV\displaystyle e_{V} = 45 mm · c1\displaystyle c_{1} = 150 mm

ψecV\displaystyle \psi_{ecV} = 0.833333

Standard and source

Standard
EN 1992-4:2018
Result
ψecV\displaystyle \psi_{ecV} in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
ψecV\displaystyle \psi_{ecV} = 0.833333 1= 1 / (1 + 2 · (45 mm) / (3 · (150 mm)))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は設計 › 接合部で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.