溶接部近傍の熱影響部(HAZ)における低減引張強さ: fu,haz = ρu,haz · fu。

fu,haz=ρu,haz⋅fu\displaystyle f_{u,haz} = \rho _{u,haz} \cdot f_{u}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Formula and quantities

SymbolNameUnitNote
ρu,haz\displaystyle \rho_{u,haz}引張強さに対するHAZ軟化係数1
fu\displaystyle f_{u}母材の特性引張強さN/m²
fu,haz\displaystyle f_{u,haz}HAZ低減引張強さN/m²Result

例題

ρu,haz\displaystyle \rho_{u,haz} = 0.6 · fu\displaystyle f_{u} = 310,000,000 N/m²

fu,haz\displaystyle f_{u,haz} = 186,000,000 N/m²

Standard and source

Result
fu,haz\displaystyle f_{u,haz} in MPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
fu,haz\displaystyle f_{u,haz} = 186,000,000 N/m²= (0.6 1) · (310,000,000 N/m²)