Progetto · Alluminio

Resistenza di progetto di saldatura testa a testa in alluminio σw,Rd (EN 1999-1-1)

  • Tipo: Proprietà
  • Versione 1
  • revisionata il 25/11/2026

Resistenza di progetto a tensione normale di una saldatura testa a testa a completa penetrazione in alluminio secondo EN 1999-1-1 punto 8.6.3.2 eq. (8.28): σw,Rd = fw / γMw.

σw,Rd=fw/γMw\displaystyle \sigma _{w,\mathrm{Rd}} = f_{w} / \gamma _{Mw}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Formula and quantities

SymbolNameUnitNote
fw\displaystyle f_{w}Resistenza caratteristica del metallo di saldatura (prospetto 8.8)N/m²
γMw\displaystyle \gamma_{Mw}Coefficiente parziale per giunti saldati (1,25)1
σw,Rd\displaystyle \sigma_{w,\mathrm{Rd}}Resistenza di progetto della saldatura testa a testaN/m²Result

Esempi svolti

EN AW-6082 con 5356 filler

fw\displaystyle f_{w} = 210.000.000 N/m² · γMw\displaystyle \gamma_{Mw} = 1,25

σw,Rd\displaystyle \sigma_{w,\mathrm{Rd}} = 168.000.000 N/m²

EN AW-6060 con 4043 filler

fw\displaystyle f_{w} = 150.000.000 N/m² · γMw\displaystyle \gamma_{Mw} = 1,25

σw,Rd\displaystyle \sigma_{w,\mathrm{Rd}} = 120.000.000 N/m²

Standard and source

Standard
EN 1999-1-1:2007, punto 8.6.3.2, Eq. (8.28)
Result
σw,Rd\displaystyle \sigma_{w,\mathrm{Rd}} in MPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
σw,Rd\displaystyle \sigma_{w,\mathrm{Rd}} = 168.000.000 N/m²= (210.000.000 N/m²) / (1,25 1)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

La ricerca parte in Progetto › Alluminio.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.