EN 1995-1-1 6.3.2 식 6.23에 따른 축압축 및 굽힘을 받는 부재의 안정성 검토: η = σc,0,d / (kc,y × fc,0,d) + σm,y,d / fm,y,d + km × (σm,z,d / fm,z,d) ≤ 1.0.

η=σc,0,d/(kc,y⋅fc,0,d)+σm,y,d/fm,y,d+km⋅(σm,z,d/fm,z,d)\displaystyle \eta = \sigma _{\mathrm{c},0,\mathrm{d}} / (k_{\mathrm{c},y} \cdot f_{\mathrm{c},0,\mathrm{d}}) + \sigma _{m,y,\mathrm{d}} / f_{m,y,\mathrm{d}} + k_{m} \cdot (\sigma _{m,z,\mathrm{d}} / f_{m,z,\mathrm{d}})
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

kcy

Formula and quantities

SymbolNameUnitNote
σc,0,d\displaystyle \sigma_{\mathrm{c},0,\mathrm{d}}섬유 방향과 평행한 설계 압축 응력N/m²
kc,y\displaystyle k_{\mathrm{c},y}y축 좌굴 저감 계수1
fc,0,d\displaystyle f_{\mathrm{c},0,\mathrm{d}}섬유 방향과 평행한 설계 압축 강도N/m²
σm,y,d\displaystyle \sigma_{m,y,\mathrm{d}}y축 설계 굽힘 응력N/m²
fm,y,d\displaystyle f_{m,y,\mathrm{d}}y축 설계 굽힘 강도N/m²
km\displaystyle k_{m}단면 계수 k_m1
σm,z,d\displaystyle \sigma_{m,z,\mathrm{d}}z축 설계 굽힘 응력N/m²
fm,z,d\displaystyle f_{m,z,\mathrm{d}}z축 설계 굽힘 강도N/m²
η\displaystyle \eta보-기둥 안정성 이용률1Result

예제

σc,0,d\displaystyle \sigma_{\mathrm{c},0,\mathrm{d}} = 6,000,000 N/m² · kc,y\displaystyle k_{\mathrm{c},y} = 0.6 · fc,0,d\displaystyle f_{\mathrm{c},0,\mathrm{d}} = 18,000,000 N/m² · σm,y,d\displaystyle \sigma_{m,y,\mathrm{d}} = 3,200,000 N/m² · fm,y,d\displaystyle f_{m,y,\mathrm{d}} = 16,000,000 N/m² · km\displaystyle k_{m} = 0.7 · σm,z,d\displaystyle \sigma_{m,z,\mathrm{d}} = 1,000,000 N/m² · fm,z,d\displaystyle f_{m,z,\mathrm{d}} = 16,000,000 N/m²

η\displaystyle \eta = 0.7993

Standard and source

Result
η\displaystyle \eta in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
η\displaystyle \eta = 0.799306 1= (6,000,000 N/m²) / ((0.6 1) · (18,000,000 N/m²)) + (3,200,000 N/m²) / (16,000,000 N/m²) + (0.7 1) · ((1,000,000 N/m²) / (16,000,000 N/m²))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

설계 › 목재에서 검색이 시작됩니다.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.