설계 · 강재

좌굴 감소계수 Phi 값

  • 유형: 계수
  • 버전 1
  • 2026. 11. 9.에 검토됨

감소계수 chi 산정을 위한 Phi 값: Φ = 0.5 · (1 + α · (λ̄ - 0.2) + λ̄²).

Φ=0.5⋅[1+α⋅(λˉ−0.2)+λˉ2]\displaystyle \Phi = 0.5 \cdot \left[1 + \alpha \cdot (\bar{\lambda} - 0.2) + \bar{\lambda}^2\right]

Call in Calculate modephi_ec3(alpha; lambda_bar)

Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

λ

Formula and quantities

SymbolNameUnitNote
α\displaystyle \alpha좌굴 곡선의 불완전성 계수–
λˉ\displaystyle \bar{\lambda}무차원 세장비–
Φ\displaystyle \Phi좌굴 곡선 매개변수 Phi–Result

예제

α\displaystyle \alpha = 0.34 · λˉ\displaystyle \bar{\lambda} = 0.91815

Φ\displaystyle \Phi = 1.0436 · Source: EN 1993-1-1:2005 식 (6.49)

Scope and standard

EN 1993-1-1 6.3.1.2절에 따른 휨 좌굴 곡선 공식.

Standard
EN 1993-1-1:2005, 6.3.1.2 (1) 절, 식 (6.49)
Result
Φ\displaystyle \Phi (dimensionless)

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Φ\displaystyle \Phi = 1.04359= 0.5 · (1 + 0.34 · (0.91815 - 0.2) + 0.91815²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

설계 › 강재에서 검색이 시작됩니다.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.