벽체 전체 높이의 시공 오차를 고려한 초기 편심: einit = hef / 450.

einit=hef450\displaystyle e_{init} = \frac{h_{\mathrm{ef}}}{450}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

einithef

Formula and quantities

SymbolNameUnitNote
hef\displaystyle h_{\mathrm{ef}}벽체 유효높이mmhef\displaystyle h_{\mathrm{ef}} > 0
einit\displaystyle e_{init}초기 편심mmResult

예제

hef\displaystyle h_{\mathrm{ef}} = 2,700 mm

einit\displaystyle e_{init} = 6 mm · Source: 수기 계산

Scope and standard

EN 1996-1-1 조항 5.5.1.1.

Standard
EN 1996-1-1-2005-a1:2012, 5.5.1.1 절, 식 (5.2)
Result
einit\displaystyle e_{init} in mm

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
einit\displaystyle e_{init} = 6 mm= (2,700 mm) / 450