설계 · 유리

유리 휨응력 활용률

  • 유형: 검토
  • 버전 1
  • 2026. 11. 13.에 검토됨

설계 휨응력 σEd와 설계 휨강도 fg,d를 비교하는 극한한계상태 검토: η = σEd / fg,d.

η=σEd/fg,d\displaystyle \eta = \sigma _{\mathrm{Ed}} / f_{g,\mathrm{d}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

σEd

Formula and quantities

SymbolNameUnitNote
σEd\displaystyle \sigma_{\mathrm{Ed}}설계 휨응력N/m²
fg,d\displaystyle f_{g,\mathrm{d}}설계 휨강도N/m²
η\displaystyle \eta이용률1Result

예제

σEd\displaystyle \sigma_{\mathrm{Ed}} = 14,400,000 N/m² · fg,d\displaystyle f_{g,\mathrm{d}} = 18,000,000 N/m²

η\displaystyle \eta = 0.8

Standard and source

Result
η\displaystyle \eta in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
η\displaystyle \eta = 0.8 1= (14,400,000 N/m²) / (18,000,000 N/m²)