設計 · 木構造

繊維直角引張応力度判定

  • タイプ:検証
  • バージョン1
  • 2026/11/10にレビュー済み

EN 1995-1-1 6.1.3式(6.3)による繊維直角引張応力の検証: η = σt,90,d / (kvol · ft,90,d) ≦ 1.0。

η=σt,90,d/(kvol⋅ft,90,d)\displaystyle \eta = \sigma _{t,90,\mathrm{d}} / (k_{vol} \cdot f_{t,90,\mathrm{d}})
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Formula and quantities

SymbolNameUnitNote
σt,90,d\displaystyle \sigma_{t,90,\mathrm{d}}設計繊維直角引張応力N/m²
kvol\displaystyle k_{vol}体積効果係数1
ft,90,d\displaystyle f_{t,90,\mathrm{d}}設計繊維直角引張強度N/m²
η\displaystyle \eta繊維直角引張応力度比1Result

例題

σt,90,d\displaystyle \sigma_{t,90,\mathrm{d}} = 320,000 N/m² · kvol\displaystyle k_{vol} = 0.95 · ft,90,d\displaystyle f_{t,90,\mathrm{d}} = 400,000 N/m²

η\displaystyle \eta = 0.842

Standard and source

Result
η\displaystyle \eta in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
η\displaystyle \eta = 0.842105 1= (320,000 N/m²) / ((0.95 1) · (400,000 N/m²))