設計 · 木構造

有効炭化深さ def (EN 1995-1-2)

  • タイプ:特性値
  • バージョン1
  • 2026/11/21にレビュー済み

EN 1995-1-2 第4.2.2項 式(4.1)によるゼロ強度層を加えた低減断面法の有効炭化深さ: def = dcharn + k0 · d0.

def=dchar,n+k0⋅d0\displaystyle d_{\mathrm{ef}} = d_{\mathrm{char},n} + k_{0} \cdot d_{0}
  • EN 1995-1-2:2004
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

yzdefd0

Formula and quantities

SymbolNameUnitNote
dcharn\displaystyle d_{charn}公称炭化深さmm
k0\displaystyle k_{0}ゼロ強度層係数(t >= 20 min で 1.0)1
d0\displaystyle d_{0}ゼロ強度層厚さ(7 mm)mm
def\displaystyle d_{\mathrm{ef}}有効炭化深さmmResult

例題

dcharn\displaystyle d_{charn} = 42 mm · k0\displaystyle k_{0} = 1 1 · d0\displaystyle d_{0} = 7 mm

def\displaystyle d_{\mathrm{ef}} = 49 mm

Standard and source

Standard
EN 1995-1-2:2004
Result
def\displaystyle d_{\mathrm{ef}} in mm

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
def\displaystyle d_{\mathrm{ef}} = 49 mm= (42 mm) + (1 1) · (7 mm)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は設計 › 木構造で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.