設計 · 木構造
留め具片側せん断耐力モードb Fv,Rk
EN 1995-1-1 8.2.2 式 8.6b による片側せん断木材-木材接合部モードb(部材2の圧壊)のせん断面あたりの特徴的耐力: Fv,Rk = fh,2,k · t2 · d。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 木材部材2の埋込み強度 | N/m² | ||
| 木材部材2の厚さ | mm | ||
| 接合具径 | mm | ||
| 特性耐力 | kN | Result |
例題
= 24,000,000 N/m² · = 80 mm · = 12 mm
= 23.04 kN
Standard and source
- Standard
- EN 1995-1-1:2004
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は設計 › 木構造で開始されます。
Miaknows the formula catalog and asks for what is missing.