設計 · 接合部

高力ボルトの導入軸力 Fp,C

  • タイプ:作用
  • バージョン1
  • 2026/11/13にレビュー済み

すべり抵抗接合における導入軸力付き高力ボルトの公称導入軸力: Fp,C = 0.7 · fub · As。

Fp,C=0.7⋅fub⋅As\displaystyle F_{p,\mathrm{C}} = 0.7 \cdot f_{ub} \cdot A_{s}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

FpCAsfub

Formula and quantities

SymbolNameUnitNote
fub\displaystyle f_{ub}ボルトの引張強度(最大値)N/m²
As\displaystyle A_{s}ボルトの引張応力面積mm²
Fp,C\displaystyle F_{p,\mathrm{C}}公称導入軸力kNResult

例題

fub\displaystyle f_{ub} = 1,000,000,000 N/m² · As\displaystyle A_{s} = 245 mm²

Fp,C\displaystyle F_{p,\mathrm{C}} = 171.5 kN

Standard and source

Result
Fp,C\displaystyle F_{p,\mathrm{C}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Fp,C\displaystyle F_{p,\mathrm{C}} = 171.5 kN= 0.7 · (1,000,000,000 N/m²) · (245 mm²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は設計 › 接合部で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.