設計 · 接合部
高力ボルトの導入軸力 Fp,C
すべり抵抗接合における導入軸力付き高力ボルトの公称導入軸力: Fp,C = 0.7 · fub · As。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| ボルトの引張強度(最大値) | N/m² | ||
| ボルトの引張応力面積 | mm² | ||
| 公称導入軸力 | kN | Result |
例題
= 1,000,000,000 N/m² · = 245 mm²
= 171.5 kN
Standard and source
- Standard
- EN 1993-1-8-2005-ac:2009
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は設計 › 接合部で開始されます。
Miaknows the formula catalog and asks for what is missing.