設計 · 接合部

ピン接合板の支圧耐力 Fb,Rd

  • タイプ:耐力
  • バージョン1
  • 2026/11/13にレビュー済み

鋼構造ピン接合における板とピンの設計支圧耐力: Fb,Rd = 1.5 · t · d · fy / γM0。

Fb,Rd=1.5⋅t⋅d⋅fy/γM0\displaystyle F_{\mathrm{b},\mathrm{Rd}} = 1.5 \cdot t \cdot d \cdot f_{y} / \gamma _{\mathrm{M0}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

t

Formula and quantities

SymbolNameUnitNote
t\displaystyle t接合板の板厚mm
d\displaystyle dピンの直径mm
fy\displaystyle f_{y}ピンまたは板の小さい方の降伏強度N/m²
γM0\displaystyle \gamma_{\mathrm{M0}}断面耐力に対する部分係数1
Fb,Rd\displaystyle F_{\mathrm{b},\mathrm{Rd}}ピン接合の支圧耐力kNResult

例題

t\displaystyle t = 25 mm · d\displaystyle d = 50 mm · fy\displaystyle f_{y} = 355,000,000 N/m² · γM0\displaystyle \gamma_{\mathrm{M0}} = 1

Fb,Rd\displaystyle F_{\mathrm{b},\mathrm{Rd}} = 665.63 kN

Standard and source

Result
Fb,Rd\displaystyle F_{\mathrm{b},\mathrm{Rd}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Fb,Rd\displaystyle F_{\mathrm{b},\mathrm{Rd}} = 665.625 kN= 1.5 · (25 mm) · (50 mm) · (355,000,000 N/m²) / (1 1)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は設計 › 接合部で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.