設計 · 接合部

長大ボルト接合の低減係数 βLf

  • タイプ:係数
  • バージョン1
  • 2026/11/13にレビュー済み

長大接合におけるボルト設計せん断耐力の低減係数 (Lj > 15 · d): βLf = 1 - (Lj - 15 · d) / (200 · d)。

βLf=1−(Lj−15⋅d)/(200⋅d)\displaystyle \beta _{Lf} = 1 - (L_{j} - 15 \cdot d) / (200 \cdot d)
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Lj

Formula and quantities

SymbolNameUnitNote
Lj\displaystyle L_{j}端部接合具中心間の接合長さmm
d\displaystyle dボルト呼び径mm
βLf\displaystyle \beta_{Lf}長大接合の低減係数1Result

例題

Lj\displaystyle L_{j} = 600 mm · d\displaystyle d = 20 mm

βLf\displaystyle \beta_{Lf} = 0.925 1

Standard and source

Result
βLf\displaystyle \beta_{Lf} in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
βLf\displaystyle \beta_{Lf} = 0.925 1= 1 - ((600 mm) - 15 · (20 mm)) / (200 · (20 mm))