垂直応力疲労検定比 (EN 1993-1-9)
EN 1993-1-9 第8(1)項による垂直応力範囲の疲労照査検定比: ηf = (γFf · ΔσE,2) / (ΔσC / γMf).
- EN 1993-1-9:2005
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 等価一定振幅応力範囲に対する部分係数 | 1 | ||
| 200万回繰返しに対する損傷等価応力範囲 | N/m² | ||
| 200万回繰返しにおけるディテール等級基準疲労強度 | N/m² | ||
| 疲労強度に対する部分係数 | 1 | ||
| 垂直応力疲労検定比 (<= 1.0) | 1 | Result |
例題
= 1 · = 55,000,000 N/m² · = 80,000,000 N/m² · = 1.15
= 0.790625