設計 · 鋼構造

損傷等価応力範囲 Δσ,E2 (EN 1993-1-9)

  • タイプ:特性値
  • バージョン1
  • 2026/11/24にレビュー済み

EN 1993-1-9 第6.2項による200万回繰返しに換算した損傷等価応力範囲: ΔσE,2 = λeq · Φ2 · Δσp.

ΔσE,2=λeq⋅Φ2⋅Δσp\displaystyle \Delta\sigma_{E,2} = \lambda_{eq} \cdot \Phi_{2} \cdot \Delta\sigma_{p}
  • EN 1993-1-9:2005
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

ΔσE,2λeq

Formula and quantities

SymbolNameUnitNote
λeq\displaystyle \lambda_{eq}損傷等価係数1
Φ2\displaystyle \Phi_{2}損傷等価動的衝撃係数1
Δσp\displaystyle \Delta\sigma_{p}疲労荷重モデルによる基準応力範囲N/m²
ΔσE,2\displaystyle \Delta\sigma_{E,2}200万回繰返しに対する損傷等価応力範囲N/m²Result

例題

λeq\displaystyle \lambda_{eq} = 0.85 · Φ2\displaystyle \Phi_{2} = 1.1 · Δσp\displaystyle \Delta\sigma_{p} = 75,000,000 N/m²

ΔσE,2\displaystyle \Delta\sigma_{E,2} = 70,125,000 N/m²

Standard and source

Standard
EN 1993-1-9:2005
Result
ΔσE,2\displaystyle \Delta\sigma_{E,2} in MPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
ΔσE,2\displaystyle \Delta\sigma_{E,2} = 70,125,000 N/m²= (0.85 1) · (1.1 1) · (75,000,000 N/m²)