構造解析 · 柱と安定性

断面圧縮耐力Nc,Rd

  • タイプ:特性値
  • バージョン1

一様圧縮に対する断面の設計耐力:Nc,Rd = (A · fy) / γM0(EN 1993-1-1式(6.10)による)。

Nc,Rd=A⋅fyγM0\displaystyle N_{\mathrm{c},\mathrm{Rd}} = \frac{A \cdot f_{y}}{\gamma_{\mathrm{M0}}}
  • General formula, independent of standards
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Nc,Rd

Formula and quantities

SymbolNameUnitNote
A\displaystyle A断面積cm²
fy\displaystyle f_{y}降伏強度N/m²
γM0\displaystyle \gamma_{\mathrm{M0}}断面耐力に対する部分係数–
Nc,Rd\displaystyle N_{\mathrm{c},\mathrm{Rd}}圧縮耐力kNResult

例題

A\displaystyle A = 53.8 cm² · fy\displaystyle f_{y} = 235,000,000 N/m² · γM0\displaystyle \gamma_{\mathrm{M0}} = 1

Nc,Rd\displaystyle N_{\mathrm{c},\mathrm{Rd}} = 1,264.3 kN · Source: 53.8 · 23.5 / 1.0 = 1264.3 kN

Scope and standard

軸方向圧縮を受ける断面等級1、2、3。

Result
Nc,Rd\displaystyle N_{\mathrm{c},\mathrm{Rd}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Nc,Rd\displaystyle N_{\mathrm{c},\mathrm{Rd}} = 1,264.3 kN= ((53.8 cm²) · (235,000,000 N/m²)) / 1

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は構造解析 › 柱と安定性で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.