EN 1993-1-8 6.2.6.7 式6.20に基づく梁フランジおよびウェブの圧縮設計耐力:Fc,fb,Rd = Mc,Rd / (hb - tfb)。

Fc,fb,Rd=Mc,Rd/(hb−tfb)\displaystyle F_{\mathrm{c},fb,\mathrm{Rd}} = M_{\mathrm{c},\mathrm{Rd}} / (h_{\mathrm{b}} - t_{fb})
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Formula and quantities

SymbolNameUnitNote
Mc,Rd\displaystyle M_{\mathrm{c},\mathrm{Rd}}梁の設計曲げ耐力kNm
hb\displaystyle h_{\mathrm{b}}梁全高mm
tfb\displaystyle t_{fb}梁フランジ厚さmm
Fc,fb,Rd\displaystyle F_{\mathrm{c},fb,\mathrm{Rd}}梁フランジ圧縮耐力kNResult

例題

Mc,Rd\displaystyle M_{\mathrm{c},\mathrm{Rd}} = 180 kNm · hb\displaystyle h_{\mathrm{b}} = 300 mm · tfb\displaystyle t_{fb} = 10.7 mm

Fc,fb,Rd\displaystyle F_{\mathrm{c},fb,\mathrm{Rd}} = 622.19 kN

Standard and source

Result
Fc,fb,Rd\displaystyle F_{\mathrm{c},fb,\mathrm{Rd}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Fc,fb,Rd\displaystyle F_{\mathrm{c},fb,\mathrm{Rd}} = 622.191 kN= (180 kNm) / ((300 mm) - (10.7 mm))