設計 · コンクリート構造
鉄筋の設計降伏強度
EN 1992-1-1に基づく鉄筋の設計降伏強度:fyd = fyk / γs。
Call in Calculate modef_yd_ec2(f_yk; gamma_s)
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 鉄筋の特性降伏強度 | N/mm² | ||
| 鉄筋の部分係数 | – | ||
| 鉄筋の設計降伏強度 | N/mm² | Result |
例題
= 500 N/mm² · = 1.15
= 434.783 N/mm² · Source: EN 1992-1-1:2004 条項 3.2.7
Scope and standard
EN 1992-1-1 3.2項に適合する鉄筋。
- Standard
- EN 1992-1-1:2004、3.2.7 (2)項、式 3.2.7 (2)
- Result
- in N/mm²
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は設計 › コンクリート構造で開始されます。
Miaknows the formula catalog and asks for what is missing.