設計 · 組積造構造

組積造壁の鉛直荷重検定比

  • タイプ:検証
  • バージョン1
  • 2026/11/13にレビュー済み

無筋組積造壁の鉛直荷重照査:η = NEd / NRd <= 1.0。

η=NEdNRd≤1.0\displaystyle \eta = \frac{N_{\mathrm{Ed}}}{N_{\mathrm{Rd}}} \le 1.0
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

NEdNRdη

Formula and quantities

SymbolNameUnitNote
NEd\displaystyle N_{\mathrm{Ed}}設計鉛直荷重kN/mNEd\displaystyle N_{\mathrm{Ed}} ≥ 0
NRd\displaystyle N_{\mathrm{Rd}}設計鉛直耐力kN/mNRd\displaystyle N_{\mathrm{Rd}} > 0
η\displaystyle η利用率–Result

例題

NEd\displaystyle N_{\mathrm{Ed}} = 312 kN/m · NRd\displaystyle N_{\mathrm{Rd}} = 468 kN/m

η\displaystyle η = 0.666667 · Source: 手計算

Scope and standard

EN 1996-1-1 条項 6.1.1.

Standard
EN 1996-1-1-2005-a1:2012、6.1.1項、式 (6.1)
Result
η\displaystyle η (dimensionless)

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
η\displaystyle η = 0.666667= (312 kN/m) / (468 kN/m)