作用・荷重 · 偶発作用
火災時設計荷重レベルの低減係数 ηfi (EN 1991-1-2)
EN 1991-1-2 / Eurocode 2 & 3 第2.4.2項による常温時終局限界状態設計作用に対する火災時設計作用の簡易低減係数 ηfi: ηfi = (Gk + ψfi · Qk1) / (γG · Gk + γQ · Qk1).
- EN 1991-1-2:2002
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 恒常荷重の特性値 | kN | ||
| 主要可変荷重の特性値 | kN | ||
| 火災時組合せ係数(psi_1,1 または psi_2,1) | 1 | ||
| 永久作用の部分係数(通常 1.35) | 1 | ||
| 変動作用の部分係数(通常 1.50) | 1 | ||
| 火災時設計荷重レベル低減係数 | 1 | Result |
例題
= 100 kN · = 60 kN · = 0.3 1 · = 1.35 1 · = 1.5 1
= 0.5244 1
Standard and source
- Standard
- EN 1991-1-2:2002
- Result
- in 1
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は作用・荷重 › 偶発作用で開始されます。
Miaknows the formula catalog and asks for what is missing.