設計 · コンクリート構造

導入直後の初期プレストレス力 Pm0 (EN 1992-1-1)

  • タイプ:特性値
  • バージョン1
  • 2026/11/25にレビュー済み

EN 1992-1-1 第5.10.3(2)項 式(5.43)による緊張または導入直後の初期プレストレス力: Pm0 = Ap · σpm0.

Pm0=Ap⋅σpm0\displaystyle P_{m0} = A_{p} \cdot \sigma _{pm0}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Pm0Apσpm0

Formula and quantities

SymbolNameUnitNote
Ap\displaystyle A_{p}PC鋼材断面積mm²
σpm0\displaystyle \sigma_{pm0}導入直後の初期PC鋼材応力N/m²
Pm0\displaystyle P_{m0}初期プレストレス力kNResult

例題

Ap\displaystyle A_{p} = 1,800 mm² · σpm0\displaystyle \sigma_{pm0} = 1,395,000,000 N/m²

Pm0\displaystyle P_{m0} = 2,511 kN

Standard and source

Result
Pm0\displaystyle P_{m0} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Pm0\displaystyle P_{m0} = 2,511 kN= (1,800 mm²) · (1,395,000,000 N/m²)