設計 · コンクリート構造

火災時鉄筋の設計強度 fsd,fi (EN 1992-1-2)

  • タイプ:特性値
  • バージョン1
  • 2026/11/21にレビュー済み

EN 1992-1-2 第2.3項 式(2.2)による高温下鉄筋の設計降伏強度: fsdfi = (ks · fyk) / γMfi.

fsd,fi=ks(Θ)⋅fykγM,fi\displaystyle f_{sd,fi} = \frac{k_{s}(\Theta) \cdot f_{yk}}{\gamma_{M,fi}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

fsdfi

Formula and quantities

SymbolNameUnitNote
ks\displaystyle k_{s}鉄筋強度の温度低減係数1
fyk\displaystyle f_{yk}鉄筋の特性降伏強度N/m²
γMfi\displaystyle \gamma_{Mfi}火災時鉄筋の部分係数(通常 1.0)1
fsdfi\displaystyle f_{sdfi}火災時鉄筋の設計強度N/m²Result

例題

ks\displaystyle k_{s} = 0.78 1 · fyk\displaystyle f_{yk} = 500,000,000 N/m² · γMfi\displaystyle \gamma_{Mfi} = 1 1

fsdfi\displaystyle f_{sdfi} = 390,000,000 N/m²

Standard and source

Result
fsdfi\displaystyle f_{sdfi} in MPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
fsdfi\displaystyle f_{sdfi} = 390,000,000 N/m²= ((0.78 1) · (500,000,000 N/m²)) / (1 1)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は設計 › コンクリート構造で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.