設計 · コンクリート構造

設計付着応力度 fbd

  • タイプ:耐力
  • バージョン1
  • 2026/11/10にレビュー済み

EN 1992-1-1 式(8.2)に基づくリブ付き鉄筋の終局設計付着応力度。

fbd=2.25⋅η1⋅η2⋅fctd\displaystyle f_{bd} = 2.25 \cdot \eta_{1} \cdot \eta_{2} \cdot f_{ctd}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

fbd

Formula and quantities

SymbolNameUnitNote
η1\displaystyle \eta_{1}付着品質係数(良好1.0、不良0.7)–
η2\displaystyle \eta_{2}鉄筋径係数(phi <= 32 mm で1.0)–
fctd\displaystyle f_{ctd}コンクリートの設計引張強度N/mm²
fbd\displaystyle f_{bd}設計付着強度N/mm²Result

例題

η1\displaystyle \eta_{1} = 1 · η2\displaystyle \eta_{2} = 1 · fctd\displaystyle f_{ctd} = 1.35 N/mm²

fbd\displaystyle f_{bd} = 3.0375 N/mm² · Source: EN 1992-1-1:2004 式 (8.2)

Scope and standard

EN 1992-1-1に基づくコンクリート中の付着鉄筋。

Standard
EN 1992-1-1:2004、8.4.2 (2)項、式 (8.2)
Result
fbd\displaystyle f_{bd} in N/mm²

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
fbd\displaystyle f_{bd} = 3.0375 N/mm²= 2.25 · 1 · 1 · (1.35 N/mm²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は設計 › コンクリート構造で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.